Mounting; General Mounting Instructions - Roland R1000 Series Manual

Double sheet detector
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0046991 / Rev. 1.6
4

Mounting

Pos : 26 /D oppel blech/Geräte/E20 Bus/4 M ontage/Montage - Allgemeine Hi nweis e @ 0\mod_1173695080093_501.doc @ 3424 @ 2 @ 1
The mounting of the Double Sheet Detector R1000 E20 determines the measurement accuracy
and the reliability of operation. The system was designed for operating in rough industrial
environments. However, the following mounting instructions should be observed in order to
minimize mechanical, thermal, and electromagnetic influences on the operation.
4.1

General mounting instructions

The enclosure for wall mounting meets IP65 and is designed for mounting the enclosure close to
the sensor location. This results in the use of shorter sensor cables with a corresponding lower
exposure to electromagnetic noise and could therefore result in better measurements.
The control unit should be installed in locations where no vibration exists and no additional heat is
transferred into the system (even better reduce the heat in the control unit). In addition the control
unit should be installed in such a fashion that it can be easily opened for service purposes. During
the operation the control unit and the sensors should be under visual control of the operating
personnel.
In case of panel or operator consoles the front panel version should be used.
Pos : 27 /D oppel blech/Geräte/E20/4 M ontage/Abmess ung en des Gerätes @ 0\mod_1192448643640_501.doc @ 4766 @ 233 @ 1
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series E20
Strong vibrations and additional heat can damage the control unit.
Attention
Manual
Mounting
41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E20

Table of Contents