CHAPTER 8
Planning Power Requirements
ACX1000 and ACX1100 Router Grounding Specifications
Grounding Points Specifications
Copyright © 2017, Juniper Networks, Inc.
ACX1000 and ACX1100 Router Grounding Specifications on page 57
ACX1100 AC Power Specifications on page 59
ACX1100 AC Power Cord Specifications on page 59
ACX1000 and ACX1100 DC Power Specifications on page 61
Grounding Points Specifications on page 57
Grounding Cable Lug Specifications on page 58
Grounding Cable Specifications on page 59
To meet safety and electromagnetic interference (EMI) requirements and to ensure
proper operation, the router must be adequately grounded before power is connected.
To ground ACX Series routers, you must connect a grounding cable to earth ground and
then attach it to the chassis grounding points using two paint-piercing washers and two
screws (not provided) (see
Two threaded holes are provided on the front of the router chassis for connecting the
router to earth ground. The grounding points fit 0.5-inch-long SAE 10-32 screws
(American). The grounding points are spaced at 0.625-in. (15.86-mm) centers.
Figure 17: Grounding Points on the ACX1000 and ACX1100 Router
ACX1000
MGMT
ALARM
CONSOLE/AUX
SYS
0
1
1— Grounding points
Figure 17 on page
57).
T1/E1
GE
0/0/4
0/0/5
0/0/6
0/0/7
0/1/4
0/1/5
0/1/6
1PPS
10MHz
IN
OUT
IN
OUT
0/0/1
0/0/2
0/0/3
0/1/1
0/1/2
0/0/0
0/1/0
0/1/7
0/2/2 (Cu)
0/2/3 (Cu)
0/2/0 (SFP)
0/2/1 (SFP)
0/2/2 (SFP)
0/2/3 (SFP)
0/1/3
0/2/0 (Cu)
0/2/1 (Cu)
COMBO PORTS
57