Initial Operation - Omron SYSMAC CVM1-PRO01-V1 Operation Manual

Teaching box with cvm1-mp702-v1 rom cassette (for motion control units)
Table of Contents

Advertisement

Initial Operation

4-1

Initial Operation

1, 2, 3...
32
This section describes the screen following power-up and explains online con-
nection with the MC Unit.
1. Turn ON the power to the PC. The following display will appear.
TBOX V1.00
MC SERIES
↑:SET
CLR:CONN
2. Press the CLR Key.
C200H-MC221
MC CONNECTED
C200H MC221 VX.X
CV500-MC421
MC CONNECTED
CV500 MC421 VX.X
CS1W-MC421
MC CONNECTED
CS1W MC421
CV500-MC221/421, CS1W-MC221/421
MON|X*
ORG|Y*
|Z*
|U*
C200H-MC221
MON|X*
ORG|Y*
|
|
Indicates the standard coordinates
Indicates the MONITOR Mode
3. Perform the necessary key operations.
Note
1. When the power is turned ON, the MONITOR mode is always displayed.
2. The MC Unit is initially set to the T.BOX LIMITED mode, which allows only
monitoring from the Teaching Box.
To perform functions other then monitoring, change the MC Unit control mode.
Teaching Box model and software version
MC Unit model and software version
CV500-MC221
MC CONNECTED
CV500 MC221 VX.X
CS1W-MC221
MC CONNECTED
VX.X
CS1W MC221
After 2 seconds the following display will appear.
0.00
0.00
0.00
0.00
0.00
0.00
Section
VX.X
Current position of each axis
Current position of each axis
4-1