Selecting The Connected Model - Omron SYSMAC CVM1-PRO01-V1 Operation Manual

Teaching box with cvm1-mp702-v1 rom cassette (for motion control units)
Table of Contents

Advertisement

Selecting the Connected Model

3-3

Selecting the Connected Model

1, 2, 3...
26
Set the model that the Teaching Box is connected to. Select "MC Series" out of
the following:
• Servodriver (Position Driver)
• MC Series (Motion Control)
• 3G2A5-NC111-EV1 Position Control Unit
• C500-NC222-E Position Control Unit
The MC Series is the default setting. When it is set to another Unit and changes
are necessary, use the procedure outlined below to set it to the MC Series. Se-
lect the model that was connected as explained in 3-1 Connecting to the MC
Unit.
1. Turn ON the power to the PC.
The following screen will be displayed.
When MC Series is selected
TBOX V1.00
MC SERIES
↑:SET
CLR:CONN
When 3G2A5-NC111-EV1 is selected
TBOX V1.00
NC111 V1/NC112
↑:SET
CLR:CONN
If "MC SERIES" is displayed here, it will not be necessary to change the set-
ting and the following procedure will not be needed.
2. Press the Up Cursor Key.
MODEL SETTING
1:MC SERIES
2:NC222
3:NC111V1/NC112B
3. Press the "1" Key. MC Series has been set.
4. To restore the initial screen, press the CLR Key.
Section
When C500-NC222-E is selected
TBOX V1.00
NC222
↑:SET
CLR:CONN
When Servodriver is selected
TBOX V1.00
SERVODRIVER
9600
↑:SET
CLR:CONN
3-3

Advertisement

Table of Contents
loading

Table of Contents