Omron SYSMAC CVM1-PRO01-V1 Operation Manual page 62

Teaching box with cvm1-mp702-v1 rom cassette (for motion control units)
Table of Contents

Advertisement

Monitoring and Changing Servo Parameters
Procedure 2
1, 2, 3...
Use the following procedure to change servo parameters.
Note Servo parameters can only be changed for the CS1W-MC221/421 and C200H-
MC221.
1. With the servo parameters displayed, press the CHG Key. The cursor will be
displayed.
MON|
SER|BACKLASH
X | (0 999)
|
The previous output status will be retained.
2. Change the values. The input methods are the same as for changing I/O sig-
nals.
Press the WRITE Key to set the data.
Note When the WRITE Key is pressed, the changed values are stored in RAM and will
be lost if the power is turned OFF. To save the changes, use the DATA SAVE
operation to store the data in FLASH memory.
5/5
0
Section
5-7
51