Omron SYSMAC CVM1-PRO01-V1 Operation Manual page 88

Teaching box with cvm1-mp702-v1 rom cassette (for motion control units)
Table of Contents

Advertisement

Error Resetting
Procedure 2
1, 2, 3...
Use the following procedure to reset an error in the Servodriver.
1. Select "2. DRIVER" from the menu shown in step 1. in procedure 1.
CS1W-MC221/421, CV500-MC221/421
[RT]
0.ALL AXES
1.X
2
2.Y
2. Using the 0 to 4 Keys, select an axis for which to reset the error.
In this example, all axes are selected.
[RT]
<ALL AXES>
RESET ERROR ?
YES / NO
Indicates the axes selected.
0: All axes; 1: X axis; 2: Y axis; 3: Z axis; 4: U axis
3. Press the YES Key to reset the error for the selected axes.
[RT]
ERROR RESET !
YES
C200H-MC221
DRIVER
[RT]
3.Z
4.U
DRIVER
DRIVER
Section
9-2
DRIVER
0.ALL AXES
1.X
2.Y
79