Changing The Mc Unit Control Mode - Omron SYSMAC CVM1-PRO01-V1 Operation Manual

Teaching box with cvm1-mp702-v1 rom cassette (for motion control units)
Table of Contents

Advertisement

Changing the MC Unit Control Mode

4-2

Changing the MC Unit Control Mode

Control Modes
Procedure
1, 2, 3...
EXT
Procedure
The MC Unit has three control modes; T.BOX LIMITED, T.BOX ENABLED, and
T.BOX RESERVED.
Note For details on these three modes, refer to 2-2 MC Unit Control Modes.
The MC Unit is initially set to the T.BOX LIMITED mode, which allows only moni-
toring from the Teaching Box. The control mode can only be changed from the
Teaching Box.
To perform other operations, the MC Unit control mode must be changed to ei-
ther T.BOX ENABLED or T.BOX RESERVED.
When an attempt is made to select a function other than monitoring, the follow-
ing error message will appear if the MC Unit is in T.BOX LIMITED mode.
CHANGE TO T.BOX
ENABLED OR T.BOX
RESERVED MODE
AND PROCEED.
When the above message appears, clear the message using the procedure out-
lined in procedure two.
Changing the Mode to T.BOX ENABLED
The following procedure shows how to change to the T.BOX ENABLED mode.
1. Press the EXT Key.
CS1W-MC421
EXT|
1.CHANGE MODE
2.SERVO LOCK
3.SERVO FREE
2. Press "1."
EXT| CHG MODE
| T.BOX
| LIMITED
1
|SWITCH:↑,↓
3. Press the Down Cursor Key.
(Press the Up Cursor Key or the Down Cursor Key to select either T.BOX
LIMITED, T.BOX RESERVED, or T.BOX ENABLED.)
EXT| CHG MODE
| T.BOX
| RESERVED
|SWITCH:↑,↓
Clearing Error Messages
The following procedure shows how to clear an error message. The procedure
to clear the error message that is displayed with the CS1W-MC421 when an EX-
TENSION mode function for the absolute encoder is selected without setting the
mode to T.BOX ENABLED is shown as an example.
EXT|
4.MEM PROTECT
5.ABS ORIG SET
6.LANGUAGE
A buzzer will sound when this error
message appears.
1/3
2/3
EXTENSION mode menu
Section
4-2
33

Advertisement

Table of Contents
loading

Table of Contents