Omron SYSMAC CVM1-PRO01-V1 Operation Manual page 85

Teaching box with cvm1-mp702-v1 rom cassette (for motion control units)
Table of Contents

Advertisement

Teaching
76
3. Press the YES Key to write the position data.
CS1W-MC221/421, CV500-MC221/421
[TH]X
Y
YES
TK1 Z
0004
Indicates the address of the next position data.
Position data is stored in series for the axes controlled by one task.
The following example shows the memory addresses when the X and Y
axes are controlled by task 1.
A0000
A1999
C200H-MC221
100.00
[TH]X
1000.0
1111.1
TK1
1111111
0002
X
Address 0
Y
Address 2
To be stored next.
Section
100.00
Y
1000.0
When the WRITE Key is pressed,
data for the two axes will be stored
and then the next address (first
address + 2) will be automatically dis-
played.