S e l e c t [ P R I N T M E N U ] > [ R E P L A C E H E A D ]
22
>[FINALIZE]. Then, select the number of the Head you
replaced and press the [ENTER] key.
When selecting the Head, move the cursor by the Left
and Right keys. Then, you can decide the Head by the
Up and Down keys. The cursor is placed at the Head1,
you can go out [REPLACE HEAD FINALIZE] menu with
pressing the Left key.
When you execute [FINALIZE], the Pressure Pump of
the replaced Head rotate 15 seconds and Head is
capped automatically. After that, the machine performs
Normal Cleaning for all Heads. When LCD shows
[REPLACE HEAD FINALIZE], [FINALIZE] is finished.
23
Perform the following operations.
1. HEAD RANK SETTING
2. THERMISTOR CHECK
3. HEAD ALIGNMENT (Refer to the section 4 "HEAD ALIGNMENT")
4. HEAD INFORMATION CLEAR
<HOW TO SET HEAD RANK>
In [HEAD RANK] menu, select the Head No. of the Head
that you just replaced and input the HEAD RANK written
on the sticker of the Head.
Press the [ENTER] key to save the settings.
* The Head No. becomes [HEAD 1], [HEAD2], [HEAD3]
from the Head at the left end in order.
SERVICE MENU
PRINT MENU
3-9
PRINT MENU
REPLACE HEAD
[
]
REPLACE HEAD
FINALIZE
[
]
FINALIZE
123456
FINALIZE
1
[ENTER]
NOW PROCESSING...
SERVICE MENU
PRINT MENU
[
]
PRINT MENU
HEAD RANK
[
] [
]
HEAD RANK
HEAD 1
[
]
HEAD 1
21.5
>
21.5
[ENTER]
Model no.1RH15130-1321
S/N *52a3G0077A21.1 *
Head Rank
[
]