Select [I/S MENU] > [I/S CONTROL] > [PRESS PUMP 1- 6] >
12
[CLOSE] and press [ENTER] key.
Put the cloth under Adapter Screw.
13
Then, loosen Adapter Screw and disconnect the ink from
Supply Pump.
Do not remove Tube Joint Adapter from Ink Tube.
Ink could be spilled from Ink Tube slowly, so it is
necessary to do this replacement promptly.
Remove O Ring from Tube Joint Adapter.
14
Replaced O Ring cannot be used again.
SERVICE MENU
I/S MENU
Adapter Screw
Supply Pump
O Ring
5-20
I/S MENU
I/S CONTROL
[
] [
I/S CONTROL
PRESS PUMP1
[
] [
PRESS PUMP1
CLOSE
[ENTER]
Tube
Tube Joint Adapter
]
]