Roland Advanced Jet AJ-1000 Service Notes page 129

Hide thumbs Also See for Advanced Jet AJ-1000:
Table of Contents

Advertisement

2) Insert the black probe to CN51-1pin(GND) and the
red probe to CN51-8pin(Vout) on the SW Power
Supply.
3) Rotate the volume in clockwise direction using the
screwdriver to adjust the output voltage value to
+41V+ 0.1.
If the value is over +41.4V, the voltage will not be
m e a s u r e d . R o t a t e t h e v o l u m e i n
counterclockwise direction in that case.
Check the following.
6
1. Heater Check
Go to [SERVICE MENU] > [HEATER MENU] >
[HEATER CHECK], select each heater and press the
[ENTER] key. And check if temperature rises.
Check same procedure as above for [PRE-R], [PRE-F],
[PRINT], [DRYER A], [DRYER B] and [DRYER C].
If you turn on the heater on this menu, it keeps
heating without controlling the temperature.
Come out from the menu after confirming the
temperature rises.
SERVICE MENU
HEATER MENU
HEATER MENU
HEATER CHECK
PRE-R
PRE-F
PRINT
DRYER A
DRYER B
DRYER C
3-44
Signal Junction
Board
CN51-8pin CN51-1pin
Probe
Volume
[
] [
]
[
]
_ 25
C
PRE-R
* 40
O
C
O
25
C
PRE-F
25
C
O
O
PREHEATER R OFF
PREHEATER R ON
[
]
25
C
O
25
O
C
[
]
_ 25
C
O
25
C
O

Advertisement