Even though the machine
carries out the regular
movement, the output of
0160
Pressure Pump 1 Sensor
does not reach the
expected value.
Even though the machine
carries out the regular
movement, the output of
0161
Pressure Pump 2 Sensor
does not reach the
expected value.
Even though the machine
carries out the regular
movement, the output of
0162
Pressure Pump 3 Sensor
does not reach the
expected value.
Even though the machine
carries out the regular
movement, the output of
0163
Pressure Pump 4 Sensor
does not reach the
expected value.
Even though the machine
carries out the regular
movement, the output of
0164
Pressure Pump 5 Sensor
does not reach the
expected value.
Even though the machine
carries out the regular
movement, the output of
0165
Pressure Pump 6 Sensor
does not reach the
expected value.
Even though the machine
carries out the regular
movement, the output of
0170
Supply Pump 1 Sensor
does not reach the
expected value.
Even though the machine
carries out the regular
movement, the output of
0171
Supply Pump 2 Sensor
does not reach the
expected value.
Pressure Pump 1 Motor has a problem.
Pressure Pump 1 Sensor has a problem.
Pressure Pump 1 Magnet has dropped out.
Wiring or Flexible Cable has short circuitted
or cut-line.
Pump Board has a problem.
Servo Board has a problem.
Pressure Pump 2 Motor has a problem.
Pressure Pump 2 Sensor has a problem.
Pressure Pump 2 Magnet has dropped out.
Wiring or Flexible Cable has short circuitted
or cut-line.
Pump Board has a problem.
Servo Board has a problem.
Pressure Pump 3 Motor has a problem.
Pressure Pump 3 Sensor has a problem.
Pressure Pump 3 Magnet has dropped out.
Wiring or Flexible Cable has short circuitted
or cut-line.
Pump Board has a problem.
Servo Board has a problem.
Pressure Pump 4 Motor has a problem.
Pressure Pump 4 Sensor has a problem.
Pressure Pump 4 Magnet has dropped out.
Wiring or Flexible Cable has short circuitted
or cut-line.
Pump Board has a problem.
Servo Board has a problem.
Pressure Pump 5 Motor has a problem.
Pressure Pump 5 Sensor has a problem.
Pressure Pump 5 Magnet has dropped out.
Wiring or Flexible Cable has short circuitted
or cut-line.
Pump Board has a problem.
Servo Board has a problem.
Pressure Pump 6 Motor has a problem.
Pressure Pump 6 Sensor has a problem.
Pressure Pump 6 Magnet has dropped out.
Wiring or Flexible Cable has short circuitted
or cut-line.
Pump Board has a problem.
Servo Board has a problem.
Supply Pump 1 Motor has a problem.
Supply Pump 1 Sensor has a problem.
Supply Pump 1 Magnet has dropped out.
Wiring or Flexible Cable has short circuitted
or cut-line.
Pump Board has a problem.
Servo Board has a problem.
Supply Pump 2 Motor has a problem.
Supply Pump 2 Sensor has a problem.
Supply Pump 2 Magnet has dropped out.
Wiring or Flexible Cable has short circuitted
or cut-line.
Pump Board has a problem.
Servo Board has a problem.
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Check Pressure Pump 1 Magnet
Pressure Pump 1 Motor replacement
Pressure Pump 1 Sensor replacement
Wiring or Flexible Cable replacement
Pump Board replacement
Servo Board replacement
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Check Pressure Pump 2 Magnet
Pressure Pump 2 Motor replacement
Pressure Pump 2 Sensor replacement
Wiring or Flexible Cable replacement
Pump Board replacement
Servo Board replacement
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Check Pressure Pump 3 Magnet
Pressure Pump 3 Motor replacement
Pressure Pump 3 Sensor replacement
Wiring or Flexible Cable replacement
Pump Board replacement
Servo Board replacement
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Check Pressure Pump 4 Magnet
Pressure Pump 4 Motor replacement
Pressure Pump 4 Sensor replacement
Wiring or Flexible Cable replacement
Pump Board replacement
Servo Board replacement
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Check Pressure Pump 5 Magnet
Pressure Pump 5 Motor replacement
Pressure Pump 5 Sensor replacement
Wiring or Flexible Cable replacement
Pump Board replacement
Servo Board replacement
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Check Pressure Pump 6 Magnet
Pressure Pump 6 Motor replacement
Pressure Pump 6 Sensor replacement
Wiring or Flexible Cable replacement
Pump Board replacement
Servo Board replacement
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Check Supply Pump 1 Magnet
Supply Pump 1 Motor replacement
Supply Pump 1 Sensor replacement
Wiring or Flexible Cable replacement
Pump Board replacement
Servo Board replacement
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Check Supply Pump 2 Magnet
Supply Pump 2 Motor replacement
Supply Pump 2 Sensor replacement
Wiring or Flexible Cable replacement
Pump Board replacement
Servo Board replacement