Roland Advanced Jet AJ-1000 Service Notes page 131

Hide thumbs Also See for Advanced Jet AJ-1000:
Table of Contents

Advertisement

Remove 4 screws in the figure and replace with the new
3
SW Power Supply(5V, 24V).
Fix it with 4 screws and connect all cables.
Fix the Signal Board Stay with 4 screws in the figure with
4
Signal Junction Board. Put all cables through Wire
Saddles and connect all cables.
Check the following.
5
1. Heater Check
Go to [SERVICE MENU] > [PRINT MENU] > [HEAD
HEATER] and press the [ENTER] key. And check if
temperature rises.
If you turn on the heater on this menu, it keeps
heating without controlling the temperature.
Come out from the menu after confirming the
temperature rises.
SERVICE MENU
PRINT MENU
PRINT MENU
HEAD HEATER
HEAD1
_ 25
3-46
Signal Junction
Board
Signal Board Stay
[
] [
]
[
]
C
HEAD1
* 30
C
O
O
HEATER OFF
HEATER ON

Advertisement

Table of Contents
loading