Remove the Network Board and fix with the new Main
7
Board.
Carry out the following operations after replacement.
8
1. DIP SW Setting
2. Firmware Installation
3. System Parameter Initialize
4. Cap & Wiper Check *2
5. Sensor Check
6. Limit Position & Max Scan Width Initialize
After performing these operations, perform
and write the parameter that was saved before replacement to the
Main Board.
Carry out the following operations if it is not possible to transfer the parameter by Peck.
1. DIP SW Setting
2. Firmware Installation
3. System Parameter Initialize
4. Head Rank Input
5. Serial Number Input *1
6. Cap & Wiper Check *2
7. Cap Height Adjustment
*1 Input the serial number in the [SERVICE MENU] > [SERIAL NO.].
*2 It can be performed in the [SERVICE MENU] > [I/S CHECK].
Head Board Connection
[Put Parameters] with Peck
8. Sensor Check
9. Limit Position & Max Scan Width Initialize
10. Linear Encoder Setup
11. Ink Type Setting
12. Head Alignment (horizontal and bidirectional direction)
13. Calibration
3-49