6-12 THE BLOWER FAN DOES NOT MOVE

NO
CHECKING POINT
Check the setting of the
1
blower fan
Check the setting of the
2
dryer temperature
Check if the heater control
3
board is broken

6-13 THE TAKE-UP/FEED OUT UNIT DOES NOT MOVE

NO
CHECKING POINT
Check the power switch in
1
the take-up/feed out unit
Check whether the cover
2
of the take-up/feed out
unit is open or closed
Check the setting of
3
AUTO switch
Check the way of the
4
media installation
Check the cable
5
connection/bad contact
Check the board of take-
6
up/feed out unit side
ACTION
REFERENCE
Turn on the setting of
User's Manual
the blower fan
Change the dryer
User's Manual
temperature except
Replace the fuse on the
heater control board
Replace the heater
control board
ACTION
REFERENCE
Turn on the power
switch
Close the cover of the
take-up/feed out unit
Check the setting of
AUTO switch
Install the media
correctly
Check the cable
[3-14 TU BOARD
connection/bad contact
REPLACEMENT]
Replace the cable
Replace the board of
[3-14 TU BOARD
take-up/feed out unit
REPLACEMENT]
The blower fan does not work unless turn on the setting of [BLOWER
FAN] in the heater menu.
The blower fan does not move when the setting of dryer temperature is
OFF.
The heater does not work correctly because the signal to the heater is
not transferred correctly.
The take-up/feed out unit does not move when the power switch is OFF
in the take-up/feed out unit.
The take-up/feed out unit does not move if the cover is open due to the
cause that the shaft is not placed correctly.
The take-up/feed out unit does not move automatically when AUTO
switch is OFF.
The take-up/feed out unit does not reflect if the media is not passed
through the guide roller and dancer roller correctly.
Check the connection/bad contact the cable between AC junction board
and the take-up/feed unit. Check this when the same symptom occurs
after removing AC junction board especially.
Replace the cable if there is a problem in the cable connection/bad
contact.
The take-up/feed out unit does not move if the problem occurs in the
take-up/feed out unit side.