• 13x: Last tightening data with fixed length string fields
Input Connection Points for Last Tightening Data
The connection points in this group will contain data about the last tightening. As such, they are
not updated after a parameter, group, or job selection until a tightening occurs.
110
Name
Tightening ID
UDINT
Time
DT
Multi Sequence
UINT
Number
Multi Number
UINT
Multi Type
USINT
Parameter
UINT
Parameter Name
SHORT_STRING
Parameter
DT
Timestamp
Tool Serial
SHORT_STRING
Number
Tightening Status
BOOL
Count
USINT
Batch
USINT
Torque Unit
ENGUNIT
Torque
REAL
Min Torque
REAL
Max Torque
REAL
Angle
UDINT
Min Angle
UDINT
Max Angle
UDINT
VIN
SHORT_STRING
Total size: 55-194 bytes
111
Name
Tightening ID
UDINT
Time
DT
Multi Sequence
UINT
Number
Multi Number
UINT
Multi Type
USINT
Parameter
UINT
Tightening Status
BOOL
Count
USINT
EYFR03 User Manual
Chapter 7: EtherNet/IPTM
Data Type
ID number of the last tightening
Timestamp of the last tightening
Sequence number of the running multi-parameter operation.
Instance number of multi-parameter operation (job or group) currently
running. Ignored if 0.
Type of multi-parameter operation currently running:
1 – Group
2 – Job
Ignored if Multi-Number is 0.
Instance number of the parameter that produced the tightening
Name of the parameter. Max length 25
Timestamp of the last change to the parameter
Serial number of the tool that produced the tightening. Max length 14
Indicates if the last tightening was accepted as valid.
Number of results performed in the current batch for the parameter.
Number of results required for a batch in the parameter.
Unit used for torque fields
Torque of the tightening just performed.
Minimum torque required for a tightening in the parameter.
Maximum torque required for a tightening in the parameter.
Angle of the tightening just performed.
Minimum angle required for a tightening in the parameter.
Maximum angle required for a tightening in the parameter.
Max length 100
Data Type
ID number of the last tightening
Timestamp of the last tightening
Sequence number of the running multi-parameter operation.
Instance number of multi-parameter operation (job or group) currently
running. Ignored if 0.
Type of multi-parameter operation currently running:
1 – Group
2 – Job
Ignored if Multi-Number is 0.
Number of the parameter that produced the tightening
Indicates if the last tightening was accepted as valid.
Number of results performed in the current batch for the parameter.