Default: 10 seconds
This setting controls how long the qualifier will wait for a response from the client when sending
a subscription notification packet, such as MID 0015 or MID 0061. If no response is received
within the specified ack timeout, the qualifier will try again, up to the specified number of
retries. If no response is received after all retries, the ACOP connection is considered broken
and will have to be re-established. This will terminate all subscriptions that were established on
that connection, regardless of which one did not receive a response.
Retries
Range: 0 to 10
Default: 3
This setting controls how many times the qualifier will resend a subscription notification packet,
such as MID 0015 or MID 0061, to the client. If no response is received within the specified ack
timeout, the qualifier will try again, up to the specified number of retries. If no response is
received after all retries, the ACOP connection is considered broken and will have to be re-
established. This will terminate all subscriptions that were established on that connection,
regardless of which one did not receive a response.
Transmit Rejects
Default: Yes
This setting determines if reject tightenings are sent to the ACOP network. If set to Yes, all
tightenings will be sent to the network. If set to No, only accepts will be sent to the network,
both cycles and batch completes. This setting does not affect if rejects are logged to the unit
storage and has no effect if the qualifier NOKs setting is not set to Report or Count.
Port
Range: 0 to 65535
Default: 4545
This setting controls the Ethernet port on which the unit listens for ACOP connections.
Cell ID
Range: 0 to 9999
Default: 0
This setting controls the value put in the Cell ID field of ACOP commands such as MID 0001
and 0061.
Channel ID
Range: 0 to 99
Default: 0
This setting controls the value put in the Channel ID field of ACOP commands such as MID
0001 and 0061.
EYFR03 User Manual
69 of 110
v1.6.0
Chapter 6: Atlas Copco Open Protocol