Flush detection delay
Default: 0
Range: 0 to 30 seconds
Delays Flush Torque Detection mode and ignores loads for a selected time period
LED light
Default: LED button
Values: LED button, Trigger switch
This setting controls how the LED on the tool is activated.
Crossthread/Rehit detection
Default: 0
Range: 0 to 3.0 seconds
If the clutch is activated before the minimum runtime set by this setting, the tool alerts the
operator to a NOK fastening.
Variable speed control
Default: Variable
Values: Variable, Single
This setting controls if the tool run speed can be controlled by use of the trigger.
Cross thread reduction
Default: Off
Range: Off, On >360° Reverse
This setting controls if the tool uses its cross-thread reduction behavior.
Retightening prevention
Default: 0
Range: 0 to 3.0 seconds
This setting controls the amount of time the tool is prevented from operating after shut-off.
Socket extension mode
Default: None
Range: None, 150mm, 250mm
This feature adjusts tool's RPM during pulsing to improve accuracy when using an extension.