This output indicates when a group is active, either because it was selected directly or as part of a
job. One copy of this field exists for each of the 100 available groups. The output will remain
active while the unit is suspended if the associated group is selected.
Job #X Active
Inputs used: 1 per job
This output indicates when a job is active. One copy of this field exists for each of the 100
available jobs. The output will remain active while the unit is suspended if the associated job is
selected.
Parameter Active (binary)
Inputs used: up to 7
This group of outputs is used together to indicate the number of the currently selected parameter.
The outputs are read together as a binary number to determine which parameter, if selected, is
active. This field will only have a value if a parameter was selected directly and will not indicate
parameters activated as part of a group or job. When a parameter is not selected directly, this
output group will read as 0. The value of this field will not be cleared during suspend.
The number of required outputs depends on the maximum parameter that will be indicated. See
the "Binary representation of active operations" section below for more details about how to
assign this field.
Group Active (binary)
Inputs used: up to 7
This group of outputs is used together to indicate the number of the currently selected group.
The outputs are read together as a binary number to determine which group, if any, is selected.
This field will only have a value if a group was selected directly and will not indicate groups
activated as part of a job. When a group is not selected directly, this group of outputs will read
as 0. The value of this field will not be cleared during suspend.
The number of required outputs depends on the maximum group that will be indicated. See the
"Binary representation of active operations" section below for more details about how to assign
this field.
Job Active (binary)
Inputs used: up to 7
This group of outputs is used together to indicate the number of the currently selected job. The
outputs are read together as a binary number to determine which job, if any, is selected. When a
job is not selected, this group of outputs will read as 0. The value of this field will not be cleared
during suspend.
The number of required outputs depends on the maximum job that will be indicated. See the
"Binary representation of active operations" section below for more details about how to assign
this field.