Panasonic EYFR03 User Manual page 32

Hide thumbs Also See for EYFR03:
Table of Contents

Advertisement

Configuration Options
Figure 29: Group Edit screen
Soft keys
1. Delete – Deletes all information in the group and returns to the Choose Group screen.
2. Parameters – Goes to the Group Parameter Select screen
3. Save – Saves changes to the group and returns to the Choose Group screen
4. Cancel [ESC] – Discards changes to the group and returns to the Choose Group screen
Name
The group name can be up to 25 numbers, letters, or decimal points.
The group name is shown on screen when running the group but is not sent to the network.
Lock on done
Default: No
This setting determines if the unit will lock or restart the group when the group is completed.
When set to Yes, the qualifier will not restart the group when all parameter batches are
completed and will require a batch reset or parameter selection command to restart the group.
When set to No, the qualifier will restart the group when it completes.
This setting is ignored when running the group as part of a job.
Batch beep on
Default: Group
Values: Group, Parameter
This setting determines if the unit will sound the batch beep for each parameter in the group or
only when the entire group is completed. The UI will show the batch color for each individual
parameter when it completes regardless of this setting.
Free run mode
Default: No
This setting determines if the group runs in standard or free run mode. When set to No, the
group will run in standard mode. When set to Yes, the group will run in free run mode.
EYFR03 User Manual
32 of 110
v1.6.0
Chapter 3: Configuring the unit
20 January 2020