Time between cycles
Default: 0
Range: 0 to 9999 seconds
This setting controls the minimum amount of time after an accepted tightening before another
tightening should be accepted. Any additional tightenings performed within this time after an
accepted tightening will be automatically considered a reject.
Time between batches
Default: 0
Range: 0 to 9999 seconds
This setting controls the minimum amount of time after a batch completion before another
tightening should be accepted. Any additional tightenings performed within this time after a
batch completion will be automatically considered a reject.

Groups

Selecting Groups
Figure 27: Main Menu - Groups
Figure 28: Choose Group screen
Soft keys
1. Select – Select the currently highlighted group to run and return to the Run screen. Only
available for selectable groups.
2. Edit – Edit the currently highlighted group.
3. Copy – Selects the currently highlighted group to be copied to another location.
4. Exit [ESC] – Returns to the Main Menu screen.
The Choose Group screen shows all the groups in the unit in a 10x10 grid. Groups may be
highlighted by using the arrow keys to move the highlight to the desired group or typing the
number of the desired group. Only the groups with parameters assigned will show their numbers
on the grid. A selectable group will have a black number. A defined but not selectable group
will be shown in red. A group is defined when one or more parameters are assigned to it. A
group will become unselectable if an assigned parameter is unselectable or multiple parameters
in the group use the same tool.