ACK Timeout
Default: 5 seconds
Range: 0 to 60 seconds
This setting controls how long the qualifier will wait for an ACK to its messages.
Retries
Default: 3
Range: 0 to 10
This setting controls how many times the qualifier will retry a message.
Keep Alive
Default: 120 seconds
Range: 0 to 3600
This setting controls how often the qualifier will send a keep alive packet to the PFCS server if
no other packets are being sent.
Parameter specific Machine IDs
When the Single Solicited Name setting is set to No, the machine IDs for each parameter can be
set from the IDs page.

Unsolicited Messages

The EYFR03 allows the PFCS network to select parameters, groups, or jobs to be selected via
the unsolicited messages. The device-specific data consists of a letter followed by a number of
1-3 digits.
The letter may be one of P, G, J, or N.
When the letter is 'N', the qualifier will stop the currently running operation and the number will
be ignored.
Otherwise, the letter indicates which type of operation to start:
• P – Parameter
• G – Group
• J – Job
The number may be 1 to 100 and indicates which parameter, group, or job to select.
Examples:
• P01 – selects parameter 1
• G30 – selects group 30
• J074 – selects job 74
• N1 – stops the running operation