Panasonic EYFR03 User Manual page 84

Hide thumbs Also See for EYFR03:
Table of Contents

Advertisement

172
Name
Item Number
UINT
Item Type
USINT
Batch Reset
USINT
Suspend
BOOL
Batch
USINT
VIN
USINT[100]
Total size: 106 bytes
181
Name
Item Number
UINT
Item Type
USINT
Batch Sizes
USINT[16]
Batch Reset
WORD
Tool Suspend
WORD
Qualifier Suspend
BOOL
Total size: 24 bytes
Note that the values in this point refer to tools, but the EYFR03 runs parameters. This means
that you must select a parameter, group, or job using the tools you want to control with this
connection point. If a tool is not active in the selected parameter, group, or job, attempts to
control them will be ignored.
Input (T->O) Connection Points
This section defines the connection points are used by EYFR03 to send output data to the
network. The connection points are in the range 100-129 and are grouped by their content.
• 10x: Connection points provided for backwards compatibility with the EYFR01. (Detailed in
the Input Connection Points for Backwards Compatibility section later in this chapter)
• 11x: Last tightening data
• 12x: Current qualifier status
EYFR03 User Manual
Chapter 7: EtherNet/IPTM
Data Type
Instance number of items to run. Deactivate any running parameter,
job, or group if 0.
Type of item to run:
0 - Parameter
1 – Group
2 – Job
Ignored if Item Number is 0.
When this value changes, the batch counts of the currently running
parameter or group is reset.
When set, suspends the unit without stopping a running parameter,
group, or job.
Sets the batch size for the selected parameter. If Item Type is not 0
(Parameter), this value is ignored. If this value is 0, the parameter size
stored in the EYFR03 will be used.
Data Type
Instance number of items to run. Deactivate any running parameter,
job, or group if 0.
Type of item to run:
0 - Parameter
1 – Group
2 – Job
Ignored if Item Number is 0.
A temporary batch size to use for each tool or 0 to make no
modification.
16-bit word with each bit used to reset the batch of a tool when set (bit
0 resets tool 1, bit 1 resets tool 2, etc.)
16-bit word with each bit used to suspend a tool (bit 0 set suspends tool
1, bit 1 set suspends tool 2, etc.)
When set, suspends the unit without stopping a running parameter,
group, or job.
Description
Description
84 of 110
v1.6.0
20 January 2020

Advertisement

Table of Contents
loading

Table of Contents