Panasonic EYFR03 User Manual page 88

Hide thumbs Also See for EYFR03:
Table of Contents

Advertisement

Multi Number
UINT
Multi Type
USINT
Parameter
UINT
Parameter Name
USINT[25]
Parameter
DT
Timestamp
Tool Serial
USINT[14]
Number
Tightening Status
BOOL
Count
USINT
Batch
USINT
Torque Unit
ENGUNIT
Torque
REAL
Min Torque
REAL
Max Torque
REAL
Angle
UDINT
Min Angle
UDINT
Max Angle
UDINT
VIN
USINT[100]
Reserved
USINT
Total size: 192 bytes
131
Name
Tightening ID
UDINT
Time
DT
Multi Sequence
UINT
Number
Multi Number
UINT
Multi Type
USINT
Parameter
UINT
Tightening Status
BOOL
Count
USINT
Batch
USINT
Torque Unit
ENGUNIT
Torque
REAL
Angle
UDINT
VIN
USINT[100]
Total size: 130 bytes
EYFR03 User Manual
Chapter 7: EtherNet/IPTM
Instance number of multi-parameter operation (job or group) currently
running. Ignored if 0.
Type of multi-parameter operation currently running:
1 – Group
2 – Job
Ignored if Multi-Number is 0.
Instance number of the parameter that produced the tightening
Name of the parameter
Timestamp of the last change to the parameter
Serial number of the tool that produced the tightening.
Indicates if the last tightening was accepted as valid.
Number of results performed in the current batch for the parameter.
Number of results required for a batch in the parameter.
Unit used for torque fields
Torque of the tightening just performed.
Minimum torque required for a tightening in the parameter.
Maximum torque required for a tightening in the parameter.
Angle of the tightening just performed.
Minimum angle required for a tightening in the parameter.
Maximum angle required for a tightening in the parameter.
Padding byte for devices requiring even connection point sizes.
Data Type
ID number of the last tightening
Timestamp of the last tightening
Sequence number of the running multi-parameter operation.
Instance number of multi-parameter operation (job or group) currently
running. Ignored if 0.
Type of multi-parameter operation currently running:
1 – Group
2 – Job
Ignored if Multi-Number is 0.
Number of the parameter that produced the tightening
Indicates if the last tightening was accepted as valid.
Number of results performed in the current batch for the parameter.
Number of results required for a batch in the parameter.
Unit used for torque fields
Torque of the tightening just performed.
Angle of the tightening just performed.
88 of 110
Description
20 January 2020
v1.6.0

Advertisement

Table of Contents
loading

Table of Contents