This chapter describes the assembly object connection points and vendor-specific objects
provided by the EYFR03. Implementation was done against EtherNet/IP
1.16 (April 2014) and the associated CIP specification edition 3.16 (April 2014)

Vendor-Specific Objects

The objects described in this section are vendor-specific objects created by C.E. Electronics
(vendor ID: 1321) to manage the configuration of the EYFR03 that does not map to existing
open objects.
Tool Object
Class Code: 64 Hex
The Tool Object represents a tool learned into an EYFR03 device. A tool may be associated
with one or more C.E. Parameter objects.
Class Attributes
ID
Access
Name
1
Get
Revision
2
Get
Max Instance
Instance Attributes
ID
Access
Name
1
Set
Name
2
Get
Last Modified
3
Get
Type
4
Set
Last Calibration
Date
5
Set
Next Calibration
Date
7
Set
Serial Number
8
Get
Cycle Count
9
Set
Cycles between
Preventative
Maintenance
10
Set
Last PM Cycle
Count
11
Get
Maintenance
Reject Options
12
Get
Required
Maintenance
EYFR03 User Manual
Chapter 7: EtherNet/IPTM
Data Type
Description of Attribute
UINT
Revision of this object
UINT
Maximum instance number
of a tool object in the
device.
Data Type
Description of Attribute
SHORT_STRING
Name of the tool displayed
on screen
DT
Last time the tool attributes
were modified
USINT
Type of tool
DT
Date of last calibration
reported by tool
DT
Recommended date of next
calibration
SHORT_STRING
Serial number of the tool
UDINT
Total number of cycles
performed by the tool.
UDINT
Number of cycles permitted
between preventative
maintenance.
UDINT
Cycle count at time of last
preventative maintenance
BYTE
Causes all results from a
tool to be rejected when one
or more of the specified
maintenance operations are
required.
BYTE
Indicates what maintenance
is currently required.
75 of 110
TM
specification edition
Semantics of Value
1
The maximum number of
tools as specified for the
product.
Semantics of Value
Maximum length is 25
characters
0 = none
1-3 = reserved
4 = battery
Maximum length is 14
characters.
Bit 0 – Calibration
Bit 1 – Cycles
Bit 0 – Calibration
Bit 1 – Cycles