This input is used to clear the ID Part 2 field from the qualifier. This input will clear the ID Part
2 regardless of the source that initially provided it (bar code or Ethernet).
Clear ID Part 3
Inputs used: 1
This input is used to clear the ID Part 3 field from the qualifier. This input will clear the ID Part
3 regardless of the source that initially provided it (bar code or Ethernet).
Clear ID Part 4
Inputs used: 1
This input is used to clear the ID Part 4 field from the qualifier. This input will clear the ID Part
4 regardless of the source that initially provided it (bar code or Ethernet).
Clear All Identifiers
Inputs used: 1
This input is used to clear the VIN and ID Parts 2-4 fields from the qualifier. This input will
clear the identifiers regardless of the source(s) that initially provided them (bar code or Ethernet).
Bypass VIN
Inputs used: 1
This input is used to bypass the requirement to have a VIN entered to perform an operation.
While this input is active, the "Require VIN to run" qualifier setting is ignored. If this input is
deactivated during an operation while the Require VIN setting is set to Yes and no VIN is
entered, the unit will be suspended.
Verify Tool #X
Inputs used: 1 per tool
This input is used to verify an individual tool. When this input is activated, the associated tool
will be assumed to be pulled from its tray.
When a verify tool input is defined, a parameter will be suspended until only the correct tool is
pulled from its tray. If a group is running, all tools active in the group must be pulled.
Verify Socket #X
Inputs used: 1 per socket
This input is used to verify a socket. When this input is activated, the associated socket will be
assumed to be pulled from its tray.
When a verify socket input is defined, any parameters with a socket specified will be suspended
until only the correct socket is pulled from its tray. If a group is running, all sockets associated
with the parameters in the group must be pulled.