Select Group #X
Inputs used: 1 per group
This input selects a group when activated. One version of this input exists for each of the 100
available groups (Select Group 1, Select Group 2, etc.). If the group is not configured with one
or more valid parameters, activating an assigned input will do nothing. Deactivating the input
does not stop the group. The group will remain selected until the group is stopped, or another
parameter, group, or job is selected.
Select Job #X
Inputs used: 1 per job
This input selects a job when activated. One version of this input exists for each of the 100
available jobs (Select Job 1, Select Job 2, etc.). If the job is not configured, activating an
assigned input will do nothing. Deactivating the input does not stop the job. The parameter will
remain selected until the job is stopped, or another parameter, group, or job is selected.
Select Parameter (binary)
Inputs used: up to 7
This group of inputs is used together to select a parameter. The inputs are read together as a
binary number to determine which parameter to activate. The current parameter will remain
selected until the inputs correspond to another configured parameter, the parameter is stopped, or
another parameter, group, or job is selected.
The number of required inputs depends on the maximum parameter that will be selected. See the
Binary selection of operations section below for more details about how to assign this field.
Select Group (binary)
Inputs used: up to 7
This group of inputs is used together to select a group. The inputs are read together as a binary
number to determine which group to activate. The current group will remain selected until the
inputs correspond to another configured group, the group is stopped, or another parameter,
group, or job is selected.
The number of required inputs depends on the maximum group that will be selected. See the
Binary selection of operations section below for more details about how to assign this field.
Select Job (binary)
Inputs used: up to 7
This group of inputs is used together to select a job. The inputs are read together as a binary
number to determine which job to activate. The current job will remain selected until the inputs
correspond to another configured job, the job is stopped, or another parameter, group, or job is
selected.
The number of required inputs depends on the maximum parameter that will be selected. See the
Binary selection of operations section below for more details about how to assign this field.
EYFR03 User Manual
60 of 110
v1.6.0
Chapter 5: Discrete I/O
20 January 2020