Panasonic EYFR03 User Manual page 77

Hide thumbs Also See for EYFR03:
Table of Contents

Advertisement

C.E. Parameter Object
Class Code: 65 Hex
The C.E. Parameter Object refers to a parameter that describes the required operation for a batch
of tightenings. This should not be confused with the Parameter Object (class code 10 hex)
defined in the open portion of the Ethernet/IP
implemented in this product line.
Class Attributes
ID
Access
Name
1
Get
Revision
2
Get
Max Instance
Instance Attributes
ID
Access
Name
1
Set
Name
2
Get
Last Modified
3
Set
Tools
5
Set
Batch
6
Get
Number of
Batches
Services
Service
Available in
Code
Class
Instance
0x05
No
Yes
0x0E
Yes
Yes
0x10
No
Yes
EYFR03 User Manual
Chapter 7: EtherNet/IPTM
TM
protocol, which has a different use and is not
Data Type
UINT
Revision of this object
UINT
Maximum instance number
of a parameter set object in
the device.
Data Type
SHORT_STRING
Name of the parameter
displayed on screen and
reported in results
DT
Last time the parameter
attributes were modified
UINT
Instance numbers of tool
used for this parameter
USINT
Batch size
UINT
Number of batches run in
this parameter
Service Name
Reset
Resets the parameter to factory defaults.
Get_Attribute_Single
Returns the contents of the specified attribute.
Set_Attribute_Single
Modifies a single attribute.
77 of 110
Description of Attribute
Description of Attribute
Description of Service
Semantics of Value
1
The maximum number of
parameters as specified
for the product.
Semantics of Value
Maximum length is 25
characters
This value resets on
powerup.
v1.6.0
20 January 2020

Advertisement

Table of Contents
loading

Table of Contents