Controller Settings Object
Class Code: 68 Hex
The Controller Settings Object represents the qualifier level settings for the EYFR03.
Class Attributes
ID
Access
Name
1
Get
Revision
Instance Attributes
ID
Access
Name
1
Get
Radio Address
2
Set
Radio Channel
3
Set
Beeper Setting
4
Set
Beeper Volume
5
Set
Batch Timeout
6
Set
Cycle Timeout
7
Set
Reject Timeout
8
Set
NOKs
9
Set
Time
10
Set
Name
Services
Service
Available in
Code
Class
Instance
0x0E
Yes
Yes
0x10
No
Yes
EYFR03 User Manual
Chapter 7: EtherNet/IPTM
Data Type
UINT
Revision of this object
Data Type
UINT
The radio address of the
device
USINT
The radio channel on which
the device is operating.
BYTE
Controls when the unit will
sound the beeper
USINT
Volume level of the beeper
ITIME
Duration to show the batch
indicator on screen.
ITIME
Duration to show the cycle
indicator on screen.
ITIME
Duration to show the reject
indicator on screen.
USINT
How the system handles
NOK results or rejects.
DT
The current system time of
the device.
SHORT_STRING
The name of the device
Service Name
Get_Attribute_Single
Returns the contents of the specified attribute
Set_Attribute_Single
Modifies a single attribute
80 of 110
Description of Attribute
Description of Attribute
Description of Service
Semantics of Value
1
Semantics of Value
Range: 1-12
Changing this value will
require all tools to be
reassociated.
Bit 0 – Beep on batch
Bit 1 – Beep on reject
Bit 2 – Beep on cycle
Range: 0-10
0 disables the beeper
If 0, the indicator does
not clear timeout.
Cannot be negative
If 0, the indicator does
not clear timeout.
Cannot be negative
If 0, the indicator does
not clear timeout.
Cannot be negative
0 – Ignore
1 – Display
2 – Report
3 – Count
Maximum length: 25