B Fiber Cleaning - Alcatel-Lucent 1850 Installation And System Turn-Up Manual

Transport service switch (tss-5) | release 5.1
Hide thumbs Also See for 1850:
Table of Contents

Advertisement

Stand-alone node set-up
............................................................................................................................................................................................................................................................
Note:
circuit pack, slide the circuit pack into the slot until it is fully seated. Then close the
faceplate latch.
Result:
off, indicating successful installation.
........................................................................................................................................................................................................................
7
If either main slot is to remain unequipped, unlatch and fully seat the 199MN apparatus
blank in the empty slot.
........................................................................................................................................................................................................................
8
If the shelf is to operate in SDH mode, (default SONET) for the VLNC2, VLNC50/52 set
the shelf mode to SDH. Configuration -> Equipment -> 1850TSS-5 select Interface
Standard SDH.
Result:
........................................................................................................................................................................................................................
9
If the shelf is to operate in SDH mode, for the VLNC60, VLNC61, and VLNV64 set the
interface mode to E1 using the CLI manual command (ALU SWITCHING) (Config)#
interface-mode e1
........................................................................................................................................................................................................................
10
If applicable set the signal rate for the PTM being used. Right click on port 1 and select.
........................................................................................................................................................................................................................
11
Configuration -> port -> signal type and select OC-3/STM-1 or OC-12/STM-4 from the
menu.
........................................................................................................................................................................................................................
12
If applicable connect OUT to IN of the first PTM of the VLNC50/52 in Main1 of the
Alcatel-Lucent 1850 TSS-5 shelf using an optical fiber jumper cable. Refer to
B, "Fiber cleaning"
Table 5-2, "LBOs for OC-n/STM-n lines" (p.
Connect OUT to IN of the second PTM of the VLNC5052 in Main1 of the Alcatel-Lucent
1850 TSS-5 shelf using an optical fiber jumper cable. Attenuate according to
"LBOs for OC-n/STM-n lines" (p.
After a few minutes the flashing FAULT LEDs extinguish on the VLNC50/52 circuit pack.
The FAULT and the CR/MJ LEDs light on the SYSCTL due to DCC alarms created by
optically looping the OLIUs. These SYSCTL LEDs remain lit until the DCC is disabled in
............................................................................................................................................................................................................................................................
5 - 6
Unlatch the circuit pack and using a gentle steady pressure on both ends of the
The circuit pack FAULT LED li
The shelf will reset upon execution of the command.
for proper fiber cleaning instructions. Attenuate according to
approximately 30 seconds then goes
ghts for
5-8).
5-8).
Circuit pack installation
Appendix
Table 5-2,
365-372-403R5.1
Issue 1 November 2008