Alcatel-Lucent 1850 Installation And System Turn-Up Manual page 99

Transport service switch (tss-5) | release 5.1
Hide thumbs Also See for 1850:
Table of Contents

Advertisement

Circuit pack installation
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
2
Identify either main 1 or main 2 on the Alcatel-Lucent 1850 TSS-5 shelf. See
"Rack-mount Alcatel-Lucent 1850 TSS-5 shelf front view" (p.
........................................................................................................................................................................................................................
3
Holding the VLNC64 circuit pack upright in your hand, turn the circuit pack 90 degrees to
the right and place the main OLIU circuit pack into either main 1 or main 2 on the Rack-
Mount Alcatel-Lucent 1850 TSS-5 shelf. Do NOT engage the circuit pack in the
backplane connector.
Note:
2 slot is to be equipped, repeat Steps 1 to 3 otherwise install a 199MN apparatus blank
to provide proper air flow for cooling. Refer to
(p.
........................................................................................................................................................................................................................
4
Check off the appropriate box in
E
O
N D
........................................................................................................................................................
VLNC35 fn-c installation
Follow this procedure if you are installing a VLNC35 10/100/ BASE-T or 100BASE-X
Fast Ethernet Private Line circuit pack.
........................................................................................................................................................................................................................
1
Remove the VLNC35 circuit pack from the packing material.
........................................................................................................................................................................................................................
2
Identify the unequipped fn-c slot on the upper right-hand side of the shelf, above the
SYCTL slot. Refer to
view" (p. 4-2)
........................................................................................................................................................................................................................
3
Holding the VLNC35 circuit pack upright in your hand, turn the circuit pack 90 degrees to
the right and place the circuit pack into the fn-c slot of the Rack-Mount Alcatel-Lucent
1850 TSS-5 shelf. Do NOT engage the circuit pack in the backplane connector.
........................................................................................................................................................................................................................
4
Check off the appropriate box in
............................................................................................................................................................................................................................................................
365-372-403R5.1
Issue 1 November 2008
The VLNC64 can occupy both main slots if equipped with any VLIU. If Main
4-10).
S
F
T E P S
Figure 4-1, "Rack-mount Alcatel-Lucent 1850 TSS-5 shelf front
for details.
"199MN apparatus blank installation"
Table I-1, "Part I installation checklist" (p.
Table I-1, "Part I installation checklist" (p.
Initial circuit pack installation
Figure 4-1,
4-2).
I-3).
I-3).
4 - 7