Stand-alone installation testing
............................................................................................................................................................................................................................................................
Note:
VLNC61 defaults the 16 DS1/E1 ports to a 0 to 110 ft. setting. If this value needs to be
changed, this procedure will be necessary.
........................................................................................................................................................................................................................
1
Connect an RS-232 cable to the RS-232 port on the VLIU labeled M1 or M2 depending on
which slot is equipped with the VLNC60.
........................................................................................................................................................................................................................
2
Connect the other end of the RS-232 cable to the PC. See
assembly" (p.
........................................................................................................................................................................................................................
3
Launch a Hyper Terminal session from the PC.
........................................................................................................................................................................................................................
4
Start -> Programs -> Accessories -> Communications -> Hyper Terminal.
Result:
........................................................................................................................................................................................................................
5
Enter a name in the window and click OK.
........................................................................................................................................................................................................................
6
If using COM1 on the PC, click OK; otherwise, connect using COM2.
........................................................................................................................................................................................................................
7
Click OK.
........................................................................................................................................................................................................................
8
The default settings are as follows;
Table 6-2 VLNC60/61 default RS-232 settings
............................................................................................................................................................................................................................................................
6 - 4
The VLNC60 defaults the eight DS1/E1 ports to a 0 to110 ft. setting. The
3-32).
A connection window opens.
Value
9600
8
None
1
None
Chapter
Description
Baud Rate
Data Bits
Parity
Stop Bits
Flow Control
LBO software settings
3,
"RS-232 cable
365-372-403R5.1