Cable and fiber installation
............................................................................................................................................................................................................................................................
Procedure
Figure 3-15 VLIU 10/100BaseT cable routing
........................................................................................................................................................................................................................
1
Label the optical fiber cables, indicating bay, shelf, main circuit pack, and direction (IN or
OUT).
........................................................................................................................................................................................................................
2
Route optical fiber cables from the interconnecting equipment up to where the optical
ports will be on the VLNC50/52 and VLNC64 circuit pack and the M2 VLNC40/42
circuit packs and VLNC35 if applicable. See
(p.
3-28). Optical fibers are fragile do not attach optical fibers to the tie bar depicted in the
figure.
........................................................................................................................................................................................................................
3
Optical fiber connections between the VLNC40/42 port 4 and either the VLNC50/52 GbE
main packs or VLNC6x packs is no longer necessary. These connections can now be made
through the backplane using CLI and TL1 commands between packs.
........................................................................................................................................................................................................................
4
Place the optical fiber cables in a protective tube or channel.
........................................................................................................................................................................................................................
5
Route the 10/100BaseT RJ-45 cables to the left along the tie bar if installed. See
Figure 3-15, "VLIU 10/100BaseT cable routing" (p.
appropriate equipment.
............................................................................................................................................................................................................................................................
3 - 3 0
10/100/1G cable installation
Figure 3-14, "Optical fiber routing"
3-30). terminate these cables on the
365-372-403R5.1
Issue 1 November 2008