Connecting adjacent network elements
............................................................................................................................................................................................................................................................
Automatic protection switching test
Description
This section provides the procedures for verifying the Alcatel-Lucent 1850 TSS-5 shelf
automatic and manual protection switching.
Note the following:
These tests do NOT simulate circuit pack failures.
•
A properly grounded wrist strap must always be worn while handling circuit packs.
•
Prior to performing each test, the shelf under test must be clear of all alarms (that is,
•
only green LEDs are lighted).
MAIN1 VLNC50/52 switch test
Proceed as follows:
........................................................................................................................................................................................................................
1
There must be cross-connects present to complete this test. Enter VT1.5 cross-connects
using the cross-connect wizard. At the system level view, Configuration ->
Cross-Connection. Then follow the wizard to establish cross-connections to the DS1
ports. See
........................................................................................................................................................................................................................
2
At the NE system level view, View -> Protection and open by clicking the + sign until you
see the path pertaining to the cross connection that was established above and enter select
at the bottom of the screen.
Result:
Note:
active path.
........................................................................................................................................................................................................................
Disconnect the optical fiber connected to the IN of the port that is the active receiver on the
3
VLNC50 circuit pack.
Result:
FAULT LED will flash on the OLIU.
........................................................................................................................................................................................................................
4
At the NE system level view, View -> Protection and open the menu until you see the path
pertaining to the cross connection that was established above.
............................................................................................................................................................................................................................................................
7 - 8
"DS1 testing procedure" (p. 6-10)
Path state information will be given including which path is in the active state.
M1-1 is associated with Ring 1 and M1-2 is associated with Ring 2. Note the
The NE and then MN/ABN alarm LED will light on the SYSCTL and the
Automatic protection switching test
for details.