Alcatel-Lucent 1850 Installation And System Turn-Up Manual page 156

Transport service switch (tss-5) | release 5.1
Hide thumbs Also See for 1850:
Table of Contents

Advertisement

Stand-alone installation testing
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
10
Login into the Alcatel-Lucent 1850 TSS-5 shelf using the following values;
Result:
........................................................................................................................................................................................................................
11
Enter user privilege mode by entering an "e" at the (ALU 1850TSS-5) prompt.
........................................................................................................................................................................................................................
12
Enter a <CR> at the password prompt.
Result:
........................................................................................................................................................................................................................
13
At the (ALU 1850TSS-5)# prompt, type: config.
Result:
........................................................................................................................................................................................................................
14
At the prompt, type: interface a-1-1.
Note:
"a-2-2", "a-2-3", "a-2-4", "a-3-1", "a-3-2", "a-3-3", "a-3-4",a-4-1", "a-4-2", "a-4-3",
and "a-4-4" for the 16 ports respectively.
........................................................................................................................................................................................................................
15
At the (interface a-1-1)# prompt, type: loopback facility.
Result:
panel.
........................................................................................................................................................................................................................
16
Connect a cable from the DS1 test set to port 1 of the VLIU panel.
........................................................................................................................................................................................................................
17
Set the DS1 test set to transmit and receive a ESF quasi-random sequence signal (QRSS)
with B8ZS linecoding.
............................................................................................................................................................................................................................................................
6 - 3 0
Prompt
User:
Password:
The default system prompt (ALU 1850TSS-5) > will be echoed back.
The default system prompt (ALU 1850TSS-5)# will be echoed back.
The system prompt (Config)# will be echoed back.
Where "interface numbers can be "a-1-1", "a-1-2", "a-1-3", "a-1-4", "a-2-1",
The interface a-1-1 is now looped back toward the RJ-45 port 1 on the VLIU
Local equipment and cross-connect tests
Value
Admin
blank
365-372-403R5.1
Issue 1 November 2008

Advertisement

Table of Contents
loading

Table of Contents