If the VLIU interface panel was shipped separate from the shelf, it must be inserted into
the top of the shelf.
........................................................................................................................................................................................................................
5
Locate the VLIU interface panel and remove from packaging.
........................................................................................................................................................................................................................
6
With the faceplate latch levers of the VLIU in an open position (45
Figure 2-1, "VLIU faceplate latches" (p. 2-7)
aligning the left and right PWB edges with the card guides. Slide the VLIU into place by
applying steady pressure to the faceplate and latch assemblies until latch levers engage the
pins of the shelf.
........................................................................................................................................................................................................................
7
Secure the VLIU interface panel in the shelf by pushing both left and right latch levers
simultaneously rotating toward the sides of the shelf until VLIU interface panel is fully
seated. See
............................................................................................................................................................................................................................................................
2 - 6
Aparatus
Code
VLIU2
VLIU10
Table 2-2
above for the VLIU interface panel descriptions
Figure 2-2, "Fully seated VLIU interface panel" (p.
Alcatel-Lucent 1850 TSS-5 rack-mount shelf installation
Comcode
Release
109659136
R5.0
109657247
R5.0
seat the VLIU interface panel into the slot,
Description
Required for the higher
density VLNC52 and
VLNC61 circuit packs
when used in conjunction
with the VLNC40.
Required for equipment
protection for the
VLNC52 and unprotected
VLNC6X circuit packs.
Cannot be used with the
VLNC40.
o
angle) as seen in
2-7).