Alcatel-Lucent 1850 Installation And System Turn-Up Manual page 68

Transport service switch (tss-5) | release 5.1
Hide thumbs Also See for 1850:
Table of Contents

Advertisement

Cable and fiber installation
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
5
Label the cables, indicating bay (if required), shelf, pack and position (9 through 28).
........................................................................................................................................................................................................................
6
Label the cables indicating bay (if required) shelf, pack and position (FN C 1- 4) if using
the VLNC35 electrical ports.
........................................................................................................................................................................................................................
7
Connect the cables onto their respective positions at the 10/100BaseT terminating
equipment.
........................................................................................................................................................................................................................
8
Check off the appropriate box in
Table 3-6 10/100 pin assignment for VLIU1 applications
Procedure VLIU2
Refer to
"Dual harness 10/100 pin assignment for VLIU2 applications" (p. 3-16)
this procedure with a VLIU2 panel.
........................................................................................................................................................................................................................
1
Obtain the 10/100BaseT cables per
cable" (p. 3-17).
........................................................................................................................................................................................................................
2
Connect one end of the cable to the respective RJ-45 connector on the access panel on the
front of the rack-mount Alcatel-Lucent 1850 TSS-5 shelf.
............................................................................................................................................................................................................................................................
3 - 1 4
Wire
Pin
Designation
1
TFEP*
2
TFEN*
3
RFEP*
6
RFEN*
Figure 3-11, "VLIU2 10/100BaseT port assignments" (p. 3-15)
Table I-1, "Part I installation checklist" (p.
Direction
Out
Out
In
In
Table 3-8, "Ethernet 10/100BaseT straight through
Ethernet cable installation
1-3).
Color
White-Green
Green
White-Orange
Blue
and
Table 3-7,
when performing
365-372-403R5.1
Issue 1 November 2008