ADC AVIDIA SWD4573I1 User Manual page 547

System configuration and management
Table of Contents

Advertisement

Information
Line Current Performance
Port
Status
Errored Seconds
Severely Errored Seconds
Coding Violation
Unavailable Seconds
Far End Errored Seconds
Far End Severely Errored
Seconds
Far End Code Violations
Far End Unavailable Seconds The number of seconds during which the line is unavailable at
Avidia System Configuration and Management User Manual
Description
The port number for which the Line current performance is
displayed (each line card has two ports).
Options:
• sonetLineNoDefect
line.
• sonetLineAIS (Alarm Indication Signal)
at the local end of the SONET line.
• SonetLineRDI (Remote Defect Indication)
alarm at the remote end of the SONET line.
The number of seconds in the current 15 minute performance
monitoring interval during which at least one Line layer bipolar
error was detected or an Alarm Indication Signal - Line (AIS-L)
error was present.
The number of seconds in the current 15 minute performance
monitoring interval during which 2,500 or more Line layer
bipolar errors were detected or an AIS-L error was present.
The number of bipolar errors detected at the Line layer.
The number of seconds during which the line was unavailable.
A line becomes unavailable at ten consecutive severely errored
seconds.
The number of seconds during which at least one Line layer
bipolar error was reported by the far-end or a Remote Defect
Indicator - Line (RDI-L) error was present.
The number of seconds during which 2,500 or more Line layer
bipolar errors were reported by the far end or an RDI-L error
was present.
The number of bipolar errors detected by the far end and
reported back to the near end.
the far end.
Chapter 26: Monitoring Network Connections
There are no errors on the SONET
There is an alarm
There is an
521