ADC AVIDIA SWD4573I1 User Manual page 187

System configuration and management
Table of Contents

Advertisement

Examples
::aps=> show
::aps=> show 12
A screen similar to the following displays.
::aps=> show
Slot
Enable
12
enable(1)
Information
Slot
Enable
Mode
WTR
Command
TrapEn
Avidia System Configuration and Management User Manual
Mode
nonRevertiveAuto(2)
Description
The slot for which the APS configuration is displayed.
Whether APS is enabled or disabled for the slot.
The configured APS mode Options:
• autonorev (non revertive auto switch)—once traffic has
switched to the protection channel it will automatically switch back
to the working channel when the system detects an error on the
protection channel and the failure on the working channel has been
cleared.
• norev (non revertive manual)—once traffic has switched to the
protection channel it will not automatically switch back to the
working channel when the failure on that channel has been cleared
(this is the default).
• rev (revertive)—once traffic has switched to the protection
channel, it will automatically switch back to the working channel
when the failure on the working channel has been cleared for a
user-specified amount of time.
When the APS is set to rev, this parameter specifies the number of
seconds the system waits before switching traffic from the protection
channel back to the working channel after a failure on the main channel
has been cleared. The range is 300 to 720 seconds. The default is 300
seconds.
Which, if any, manual APS commands are in effect.
Whether APS trap generation is enabled or disabled.
Chapter 8: Configuring ATM Virtual Circuits
WTR
Command
300
none
TrapEn
enable(1)
161

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avidia switchware version 2.0

Table of Contents