ADC AVIDIA SWD4573I1 User Manual page 295

System configuration and management
Table of Contents

Advertisement

Examples
::cell=> line 18.1
::cell=> line
A screen similar to the following displays.
::cell=>line 18.1
Port
SDSL_State
18.1
down(2)
:cell=>line
Port
SDSL_State
18.1
down(2)
18.2
down(2)
18.3
down(2)
18.4
down(2)
The following table describes the information displayed by a line command.
Information
Port
SDSL_State
SNR
Atn
Avidia System Configuration and Management User Manual
SNR
Atn
0
0
SNR
Atn
0
0
0
0
0
0
0
0
Description
The slot and port for which the statics are displayed.
The current status of the SDSL cell loop. Options:
• Up
The line is up.
• Down
The line is down.
• Hand
The line is trying to connect.
• Test
The line is in test mode.
• Fail
The line has failed.
The signal-to-noise ratio margin of the signal received in dB.
The measured difference between the total signal power transmitted by the
sending unit and the total signal power received by the receiving unit in dB.
Chapter 12: Monitoring Subscriber Connections