Monitoring SDSL Frame Alarms
A screen similar to the following displays.
::frame=>alarm 3.7
Port
LOSW
3.7
0
::frame=>alarm
Port
LOSW
3.1
0
3.2
0
3.3
0
3.4
0
3.5
0
3.6
0
3.7
0
The following table describes the SDSL frame alarm history information that displays when you
type the display alarm command.
Alarm Type
Slot
Port
LOSW
Margin (Network/Customer) The number of seconds the actual margin exceeded
ES (Network/Customer)
UAS (Network/Customer)
332
Network
Margin
ES
UAS
0
0
0
Network
Margin
ES
UAS
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Description
The slot and port of the card for which the alarm
information is displayed.
Loss of Sync Word. The number of seconds during
which one of the SDSL frame loops was out of sync.
the configured threshold.
Errored Seconds. The number of seconds during
which errors occurred that prevented the payload
from being corrected.
Unavailable Seconds. The number of seconds during
which the line was unavailable. Unavailable seconds
are seconds during which the SDSL frame loop is not
synchronized.
Customer
Margin
ES
UAS
0
0
Customer
Margin
ES
UAS
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Avidia System Configuration and Management User Manual
0
0
0
0
0
0
0
0

Advertisement