ADC AVIDIA SWD4573I1 User Manual page 505

System configuration and management
Table of Contents

Advertisement

Status Box
Admin Status
Channel Slot
Channel Port
Line Slot
Line Port
Line VPI
Line VCI
Data Link LMI Type
Data Link Poll Interval
Data Link Inquiry Interval
Data Link Error Threshold
Data Link Monitor Events
Avidia System Configuration and Management User Manual
Chapter 23: Configuring Frame Relay Interworking
Description
The administrative status of the frame channel card
and line card connection: Up (activated) or Down
(deactivated).
The frame card slot number.
The frame card port number.
The line card slot number.
The line card port number.
The fr VPI of the fr VCC between the frame channel
card and the line card.
The fr VCI of the fr VCC between the frame channel
card and the line card.
The Local Management Interface type, which defines a
method of exchanging status information between the
customer device and the network. The options are:
None—no LMI support
Rev-1—LMI Rev-1
Annex A—ITU 0.933 Annex-A
Annex D—ANSI T1 617 Annex-D
If the LMI type is set to None, the poll interval, inquiry
interval, error threshold, and monitor events
parameters are not used.
The poll interval value, which is the number of seconds
between LMI status inquiry messages (range: 5-30).
The inquiry interval value, which is the number of poll
intervals before a full status inquiry message is sent
(range: 1-255).
The error threshold value, which is the number of
consecutive poll intervals in which the LMI status
inquiry messages are not received that are required for
the link to be declared down (range: 1-10).
The monitor events value, which is the number of poll
intervals in which the LMI status inquiry messages are
not received that are required for the link to be
declared down (range: 1-10).