Configuring and Initiating OAM Loopbacks
[-count <count>]
The total number of cells to be sent (cells are sent one at a time). The range is 1 to 10.
[-timeout <sec>]
The number of seconds allowed for the looped back cells to return to the originating device
before the loopback is designated as failed. The range is 5 - 15.
[-delay <sec>]
The number of seconds the system will wait between transmitted cells. The range is 5 to 15.
[-trap (send|donotsend)]
Type -trap send to enable the system to send a trap when the loopback is completed.
Type -trap donotsend if you do not want the system to send a trap.
[-location <location>]
The OAM location ID of the device where the cells will be looped back to the originating
device (format xx:xx:xx:xx:xx:xx:xx: xx:xx:xx:xx:xx:xx:xx:xx:xx where x is an integer 0 - 9
or an alpha character a - f.
Example
::atm=> f5oamloopback 4.2 0 100 -type segment -count 10 -timeout
15 -delay 5 -trap send -location ff:ff:ff:ff:ff:ff:
ff:ff:ff:ff:ff:ff:ff:ff:ff:ff: