::ds3=> show 4.1
::ds3=> show
The following screen illustrates an example of a show ds3 command.
::ds3=> show 12.1
THE DS3 CONFIGURATION TABLE FOR PORT 12.1
Circuit Identifier:
Transmit Clock Source:
Line Status Last Change:
Line Status Change Trap Enable:
Ds1 For Remote Loop:
Information
Time Elapsed
Valid Intervals
Line Type
Line Coding
Send Code
Avidia System Configuration and Management User Manual
Time Elapsed:
Valid Intervals:
Line Type:
Line Coding:
Send Code:
Cell Scrambling :
Framing Mode :
Line Status:
Invalid Intervals:
LBO:
Loop Back Status:
Channelization:
Admin Status:
Descriptions
The number of seconds that have elapsed since the current
15-minute data collection period began.
The number of 15-minute data collection intervals for which
data is collected. The Avidia system supports 96 intervals, or
24 hours, of data collection.
The type of DS3 line. Options:
• dsx3m23
• dsx3CbitParity (this line type is not currently supported)
The type of coding on the line. B3ZS is the only line type
currently supported.
The type of data currently being transmitted. Currently, only
SendNoCode is supported, indicating that the line is sending
looped or normal data.
Chapter 7: Configuring Network Services
3213
96
CbitParity
B3ZS
SendNoCode
Enabled
Direct
LOS
localTiming
0
0 to 225 feet
Wed, Dec 06 2000 11:19:19
Enabled
NoLoopback
disabled
1
Up
151