Description
The current status of the ADSL loop. Options:
• noDefect
—
There are no errors on the line.
• lossOfLink—The ATU-C was unable to link with the
ATU-R.
• lossOfFraming
—
The line is not receiving valid
frames.
• lossOfSignal
—
The line is not receiving valid
signal.
• lossOfPower
—
The line is not receiving power.
• lossOfSignalQuality
—
below the configured target margin or the BER
-7
exceeds 10
.
• dataInitFailure
—
The ATU was unable to initialize.
• configInitFailure
—
The ATU was unable to
initialize because the ATU at the other end does not
support the requested configuration.
—
• protocolInitFailure
initialize because of an incompatible protocol used
by the peer at the other end.
• noPeerAtuPresent
—
initialize because no activation sequence was
detected from the ATU at the other end.
The vendor ID of the ATU-C and the ATU-R. not
allocated means there is no ATU-R present in the
circuit.
The version number of the ATU-C and the ATU-R.
The margin has fallen
The ATU was unable to
The ATU was unable to