Monitoring IDSL Alarm Status
A screen similar to the following displays.
::idsl=> alarm 5.2
*****
Network Hourly Errored Seconds (ES):
Network Hourly Severely Errored Seconds (SES):
Network Daily Errored Seconds (ES):
Network Daily Severely Errored Seconds (SES):
Customer Hourly Errored Seconds (ES):
Customer Hourly Severely Errored Seconds (SES):
Customer Daily Errored Seconds (ES):
Customer Daily Severely Errored Seconds (SES):
Network
indicates statistics for the upstream direction, toward the network.
statistics for the downstream direction, toward the customer.
Information
Port
Loss of Signal (LOS)
Hourly Errored Seconds (ES)
(Network/Customer)
Daily Errored Seconds (ES)
(Network/Customer)
Hourly Severely Errored Seconds (SES)
(Network/Customer)
Daily Severely Errored Seconds (SES)
(Network/Customer)
Last Time Change
338
THE IDSL ALARM STATUS TABLE FOR PORT 5.2
Loss of Signal (LOS):
Last Change:
Description
The slot number and port number for which alarm
status is displayed.
The Loss of Signal alarm status (active or inactive). An
LOS alarm is reported when the signal is lost or when
40 consecutive ISDN frames are lost.
The Hourly Errored Seconds alarm status (active or
inactive).
The Daily Errored Seconds alarm status (active or
inactive).
The Hourly Severely Errored Seconds alarm status
(active or inactive).
The Daily Severely Errored Seconds alarm status
(active or inactive).
The date and time the alarm status changed.
inactive(1)
active(2)
inactive(1)
inactive(1)
inactive(1)
inactive(1)
inactive(1)
inactive(1)
inactive(1)
Thu, Jan 01 1970 00:00:00
Avidia System Configuration and Management User Manual
*****
Customer
indicates