SATO SG112-ex Operator's Manual page 98

Hide thumbs Also See for SG112-ex:
Table of Contents

Advertisement

4 Operation and Configuration
DEFAULT ROUTER
Set the default router of IPv6.
Note
Shows only if the LAN interface is selected.
PORT NUMBER
Set the LAN port numbers, 1 to 3.
The setting range is from 00001 to 65535.
The setting details is as follows:
Port Number
1
2
3
Note
• Shows only if the LAN interface is selected.
• Each port (1, 2 and 3) must be set to different values.
• When changing the port number, it is recommended to set to 1024 and
above.
• The setting will be effective only if you power on the product again.
PROTOCOL
Set the communication protocol.
• STATUS3: When selected, the product will proceed to the IGNORE
CR/LF screen.
• STATUS4: When selected, the product will proceed to the STATUS
REPLY TIMING screen.
• STATUS5: When selected, the product will proceed to the ITEM NO.
CHECK screen.
96
SG112-ex Operator Manual
Initial
Description
Value
Status 3, 5
1024
Bi-Directional Port
1025
Not applicable
9100
Bi-Directional Port
Status 4
Input port
Output port
Bi-Directional Port

Hide quick links: