4 Operation and Configuration
SUB PORT
Select the connected interface for use with the sub port.
The options are as follows:
• USB
• LAN
• RS-232C
• IEEE1284
• NONE
Note
• You cannot select the interface that has already been set for the DATA
PORT.
• The setting will be effective only if you power on the product again.
EXTERNAL DEVICE
Enable or disable the connection between the sub port and the external
device.
• ENABLE: Connecting the sub port and the external device.
It's possible to import the data from the external port into the print data
by using in the combination with an extended command.
• DISABLE: Not connecting the sub port and the external device.
It's possible to monitor the product status.
Note
Shows only after changing SUB PORT setting.
IGNORE CR/LF
Ignore or acknowledge the CR/LF code of the received data.
• YES: Ignore the CR/LF code.
• NO: Do not ignore the CR/LF code.
Note
Shows only if the DATA PORT is selected.