Error
No.
Message
Overheat error
26
Command error
27
Note
This screen shows
only when
COMMAND
ERROR in
ADVANCED
MODE is set to
ENABLE.
CRC check error
35
LED/Buzzer
ONLINE: Flashes
The temperature of the
green
product has exceeded its
STATUS: Flashes
tolerance value.
red.
LABEL: Off
RIBBON: Off
One long beep.
To clear the error:
Stop the operation of
the product and wait
until the temperature
decreases.
ONLINE: Off
Incorrect command or
STATUS: Lights red.
parameter in the print
LABEL: Off
data.
RIBBON: Off
For details of the error,
check the "Caaa: <bb>:
Three short beeps.
cc" part at the bottom of
the screen.
To clear the error:
Caaa: position of error
Press the LINE
occurrence
button.
<bb>: error command
name
cc: error code
ONLINE: Flashes
The CRC code of the data
green
to be sent (one item) is
STATUS: Flashes
incorrect.
red.
LABEL: Off
RIBBON: Off
Three short beeps.
To clear the error:
Press the LINE
button or cancel the
print job.
Cause
Countermeasure
Stop the operation of the
product to let the
temperature decrease.
Check the print data.
Refer to
More Information about
Command Error
details.
Check the data to be sent
and the communication
settings.
LINE button: Continue
printing from the print data
where the CRC error
occurred.
Send the SUB command:
Clear the CRC error and
continue printing from
where it stopped.