Delta AS Series Operation Manual page 80

Hide thumbs Also See for AS Series:
Table of Contents

Advertisement

Functional specifications
Analog-to-digital
conversion
*1
Rated input range
Average function
Self-diagnosis
*1: If the measured temperature exceeds the upper limit, it only shows the maximum value. If the
measured temperature is below the lower limit, it only shows the minimum value.
2 - 4 6
C h a p t e r 2 S p e c i f i c a t i o n s a n d S y s t e m C o n f i g u r a t i o
Centigrade (°C)
Type J: -100°C~1200°C
Type K: -100°C~1,350°C
Type R: 0°C~1,750°C
Type S: 0°C~1,750°C
Type T: -150°C~400°C
Type E: -150°C~980°C
Type N: -150°C~1,300°C
Type B: 200°C~1,800°C
Range: 1~100
Disconnection detection
Fahrenheit (°F)
Type J: -148°F~2,192°F
Type K: -148°F~2,462°F
Type R: 32°F~3,182°F
Type S: 32°F~3,182°F
Type T: -238°F~752°F
Type E: -238°F~1,796°F
Type N: -238°F~2,372°F
Type B: 392°F~3,272°F
n
Input impedance
±100mV